TOYO XP PARACON is AC Power Regulation unit that controls heat sources at Steel industry, Semiconductor industry, Molding Equipment industry, Air Conditioning industry, Fook Processing industry, Ceramic industry, Painting industry Temperature.
☆Feature 1. Wide variety of product lineup! Eleven types with current rating of 20A to 600A are available for each of single-phase and three-phase series to meet diverse needs. 2. Sophisticated functions are available as option! Current regulating / Voltage regulating / Power regulating functions, heater breakage detection function, and optional. The "Sheet-key setting unit" shows load status such as current, voltage and power with 7-segment indication. 3. More thorough standard equipment! Various functions including current-limiting, over current detection, fast-blow fuse, thyristor error detection which were optional to old models are now included as standard equipment. Moreover, error detection function and anomalous power with 7-segment indication facilitate maintenance. 4. Strong, slim, compact structure! Board mounting area ratio is improved : CT (Current Transformer) and an optional PT (Potential Transformer) can be contained in the compact body. 5. Sheet-key setting unit renders maintenance unnecessary (option) Load status of various function settings and optional functions are displayed for more user-friendliness. Error code corresponding with the detected error is detected to facilitate maintenance.
☆Model no. Descriptions XP1-20 050-L 1 1 0 S0 @ A B C DEFG @AC Power phase ;- XP1 : Single phase XP3 : Three phase APower voltage 10 : 100V 11 : 110V 20 : 200V 22 : 220V 38 : 380V 40 : 400V 44 : 440V 46 : 460V 48 : 480V BRated current 020 : 20A 030 : 30A 050 : 50A 075 : 75A 100 : 100A 150 : 150A 200 : 200A 250 : 250A 350 : 350A 450 : 450A 600 : 600A CControl method L : Phase control with current Limiting function C : Phase control with Current regulating function V : Phase control with Voltage regulating function P : Phase control with Power regulating function DInput signal 1 : Current signal 4 - 20mA 3 : Voltage signal 1 - 5V 4 : Resistance value signal 0 - 135Ω 5 : High - Low EHeater breakage function 0 : Without heater breakage function 1 : With heater breakage function FVolume to be used (selectable) Current-emitting volume Gain volume 0 : using internal VR using internal VR 1 : using internal VR using external VR 2 : using external VR using internal VR 3 : using external VR using external VR GIdentification of extra type (Blank : standard) S0 : 6-arm control (3-phase, 3-Line method) S1 : 6-arm control (3-phase, 4-Line method) * Reference Please specify below;- 1) Type in the model selection table. 2) Power source / Voltage power specifications, bad capacity, type of heater, etc.. 3) Control type / Input signal Option of phase control and kind of input signal. 4) Presence or absence of heater breakage function 5) Selection of volume to be used. 6) Others : Presence or absence of sheet-key setting accessories or others.
|